tijit pte ltd Fx/Ph (65) 65626375   66658957   

CONTACT
PROFILE
NEWS
EMAIL US

 

Home
News Page One

email: tijit@singnet.com.sg

 

Victor 11+, 14+, 15+ all new design

March 2008 saw the launch of a new addition to the high accuracy series of Calibrators, the Plus series.

There are three new types of the latest design for quick manipulation of the output simulation signals to the panel.

All the three share one common key feature: Individual key for each digit, quick setting of the simulation signal output, and more variants of the Standard Simulation. For example, for RTD, we now have PT100, PT200, PT500, PT1000 for 2-wire, 3-wire and 4-wire hard-configuration.

  1. VC 11 Plus - Process Source Calibrator

  2. VC 14 Plus - Temperature Calibrator

  3. VC 15 Plus - V/mA  Processs Calibrator

The VICTOR + Series of Handheld Calibrators

Victor 15 Plus:
Source Function Reference Range Resolution Accuracy Remark
DCV 1000mV  -100.000mV ~ 1100.000mV 10µV 0.02 + 0.01 Maximum Output current 2mA
10V  -1.0000V ~ 11.0000V 0.1mV 0.02 +0.01 Maximum Output current 5mA
DCA 20mA 0.000mA ~ 22.000mA 1µA 0.02 +0.02 External supply for simulate mA: 5V-28V       Max. load 1kΩ at 20mA
Frequency 100Hz 1.00Hz ~ 110.00Hz 0.01Hz ±2 count Output voltage: 1~11 Vp-p  (aero base waveform);   Amplitude accuracy: ±(10% +0.5V)    Max load: >100kΩ   Duty cycle: 50%
  1kHz 0.100kHz ~ 1.100kHz 1Hz
  10kHz 1.0kHz ~ 11.0KHz 0.1kHz
Pulse 100Hz 1 ~ 100000 cycles 1 cyc NA Output voltage: 1~11 Vp-p  (aero base waveform);   Amplitude accuracy: ±(10% +0.5V)    Max load: >100kΩ   Duty cycle: 50%
1kHz
10Khz
LOOP 24V     ±10% Max. current: 25mA short circuit protected
Pressure Determined by pressure module Determined by pressure module For more details, refer to the prssure module specs.
Measure Function Reference Range Resolution Accuracy Remarks
DCV 200mV  -20.00mV ~ 220.00mV 10µV 0.02 + 0.02 Input Resistance : 100MΩ
  5V  -0.5000V ~ 5.5000V 0.1mV 0.02 +0.01 Input Resistance : 1MΩ
  50V  -5.000V ~ 55.000V 1mV 0.03 +0.01  
DC mA 50 mA  -4.000 mA ~ 55.000mA 1µA 0.02 + 0.01 Input Resistance 5Ω
Frequency 500Hz 3Hz ~ 500.00Hz 0.01Hz ±2 digit Input impedance: 100 kΩ at least. Sensitivity: 3Vp-p minimum
5kHz 3Hz ~ 5,0000kHz

 

Calibrate Pressure Switch

Calibrate 2-wire Pressure Transmitter

Calibrate Pressure - Voltage Transmitter

Measuring Pressure

 

Latest News

 
  • Friday, May 13, 2005

    • Registration of TIJIT PTE LTD company in Singapore
    • Business Plan and Mission Statement
 
 

 

Digital is our name, Portable is our game


Home | News Page One

Questions or problems regarding this web site should be directed to tijit@singnet.com.sg.
Copyright © 2005 TIJIT PTE LTD. All rights reserved.
Last modified: 11/16/07.